Ask AI
Products · Engineer tools

ATT — Automated Test Tool

Commissioning

Scripted commissioning and function tests for crane deliveries. Runs test sequences against the PLC and verifies signal ranges, interlocks and motion functions; generates a signed test report per crane.

Status v2.8 · 12 sequences
Runs onEngineer laptop (Windows), connected to the PLC test interface via service port (VLAN 99)
Version2.8.3 (Aug 2026)
OwnerCommissioning · #lh-commissioning

At a glance

Used by
Commissioning & service engineers on site
Connects via
Service port 12 (VLAN 99) to the PLC test interface
Reports
Signed PDF archived in Masterdata under the crane unit page
Test sequences
Hoist interlocks, trolley/bridge limits, brake timing, overload trip, e-stop chain, anti-sway

Typical workflow

  1. Connect the laptop to service port 12; confirm a 192.168.99.x address.
  2. Open ATT → New test run → select the crane unit from Masterdata (unit ID on the e-house door).
  3. Run the sequence pack for the crane type. Failed steps are re-runnable individually.
  4. Sign & export — the report is uploaded to Masterdata automatically when online, otherwise saved locally and synced later.
ATT only reads PLC values and triggers test functions through the PLC test interface. It never writes production parameters.
Internal use only · Lifting & Handling engineering · maintained by Product Engineering
Owner: Commissioning · Updated 21 Aug 2026